MGA Prime
Regular price$0.00
/
For long time measurement of industrial combustion, large boilers gas engines and turbines, furnaces and many more
Basic Equipment
- Precise and very stable offset measuring technique using special non dispersive infrared (NDIR) technique, for enhanced long time measurements
- Up to 8 gas NDIR measurement: CO/CO2/C3H8/CH4/SO2/NO/NO2/N2O and oxygen with either long-life O2-ECS or O2-PM (paramagnetic cell)
- Remote display through MRU4U App over bluetooth on smartphone or tablet or trough VCN server via LAN/WLAN
- 7” high-resolution (800×480 pixel) TFT color display with swipe and touch technique as for smartphones, with LINUX operating system
- Intuitive icons and country specific language on display
- Modern and robust design, Aluminum enclosure with rubber molded impact Protection for use in harsh industrial environment
- Advanced algorithms to control analyzer’s operation e.g. warming up, compensation of cross-sensitivity values, and response time; all of which have impact on the quality and performance
- Measurement of many additional parameters:Temperatures (ambient and flue gas)
- Pressures (atmospheric and differential)
- Internal sample flow monitoring
- Measurement of flue gas flow velocity (using of Pitot tube) and calculation of stack gas flow rate
- Calculation of all combustion parameters likeheat loss, combustion efficiency, excess air coefficient, dew point temperature and others
- Results stored in database – possibility to view entire measurement session in graphical form, create measurement reports, export data to CSV files, and more
- PC communication via LAN – Ethernet
- Wireless data transfer via WLAN dongle
- Long distance data transfer via RS485 cable
- Analog outputs (8-channels), analog inputs (4-channels)
- SAMPLE GAS CONDITIONING: Dual gas cooler (Peltier) with dual condensate draining pumps, with constant dew point +5°C when connected to mains power supply
- Condensate monitoring and alarm on display
- Strong gas sampling pump, regulated flow of approx 1l/min
- Gas sampling probe heated, with exchangeable probe tubes, including K-type thermo-couple for flue gas temperature measurement
- Heated sampling line, Teflon 6/4mm, 9.84′ or 16.4′ or 32.81′ (3 m – 5 m – 10 m) and other lengths>
Technical Data
Gas measurement | Method |
Meas. range
(0…min / max) |
Resolution | Accuracy ** |
O2 – Oxygen | ECS | 0 to 25.00 % | 0.01 % | 0.2 % |
O2 – Oxygen | PM | 0 to 25.00 % | 0.01 % | 0.1 % |
CO2 – Carbon monoxide | NDIR | 0 to 5 / 40% | 0.01 % | ± 0.2 % or 2 % reading |
CO – Carbon dioxide | NDIR | 0 to 200 / 10,000 ppm | 1 ppm | ± 4 ppm or 2 % reading |
HC – Hydrocarbons as CH4 | NDIR | 0 to 500 / 10,000 ppm | 1 ppm | ± 10 ppm or 2 % reading |
HC – Hydrocarbons as C3H8 | NDIR | 0 to 200 / 10,000 ppm | 1 ppm | ± 10 ppm or 2 % reading |
NO – Nitric oxide | NDIR | 0 to 250 / 4,000 ppm | 1 ppm | ± 5 ppm or 2 % reading |
NO2 – Nitrogen dioxide | NDIR | 0 to 200 / 1,000 ppm | 1 ppm | ± 4 ppm or 2 % reading |
SO2 – Sulfur dioxide | NDIR | 0 to 200 / 4,000 ppm | 1 ppm | ± 4 ppm or 2 % reading |
N2O – Nitrous oxide | NDIR | 0 to 200 / 1,000 ppm | 1 ppm | ± 4 ppm or 2 % reading |
OTHER MEASUREMENTS / CALCULATIONS | Method | Measuring range | Resolution | Accuracy ** |
Tgas – stack gas temperature | NiCrNi | 32°F to 2.192°F K-type | 1°F | ± 2°F or 2 % reading |
Tair – combustion air temperature | NiCrNi | 32°F to 932°F K-type | 1°F | ± 2°F or 2 % reading |
Tamb – ambient air temperature | RTD | 32°F to 212°F PT2000 | 1°F | ± 2°F or 2 % reading |
Diff.pres. – differential pressure | Piezoresistive | -48 to +48 inH2O | 1 Pa | ± 2 Pa or 1 % reading |
GasFlow – flow velocity – differential pressure | Pitot | 3 … 100 m/s | 1 m/s | ± 1 m/s or 1 % reading |
AUX – auxiliary connector –
standardized external signal |
Software | for K-thermocouple, 0 … 10 Vdc , 4 … 20 mA, RS485 | ||
Combustion calculations – fuel type dependent | Software | heat loss, ExcAir, Air Ratio (λ), dewpoint | ||
Emission calculations | Software | mg/Nm3 , reference to O2 , g/kWh, g/s , kg/h |
GENERAL TECHNICAL DATA | |
Operating system | LINUX |
Display, operation | 7“ TFT (800 x 480 px) colour display, backlit, with touch pad |
Data storage type /capacity | internal 10.000 data sets, external USB stick |
Interface to external PC/notebook | Ethernet, WLAN, RS485 |
Cable communication interface | RS485, RJ45 (Ethernet) |
Wireless communication | WLAN |
Thermal printer | external only |
Analog output 4 – 20 mA/analog input 4 – 20 mA | 8 channel out / 4 channel in/user configurable |
Universal analog input – AUX – | 0…10 Vdc / 4…20 mA / NiCrNi / RS485 |
System warming up time | 30 minutes (typical) |
Warming up temperature NDIR bench | 131°F (55 °C) |
Mains free operation time / stand-by only | 1 hour |
Internal battery | Li-Ion , 96W, for standby |
Operating conditions | 41°F to 113°F, RH up to 95% non condensing |
Storage temperature | -4°F to 122°F |
Power supply / consumption | 86 to 265 Vac / 47…63 Hz / 105 W (analyzer only) |
Enclosure material | aluminum, rubber molded impact protection |
Protection class | IP20 (or IP42 inside transport case) |
Dimensions | 16.92“ x 11.41“ x 5.9“ (WxHxD) |
Weight | from 16.5 lbs. for minimal configuration |
* overload range of ECS is usable only for short duration ** which ever is larger
-